- Up to 256 inputs and 32 outputs
- Simultaneous use of up to 16 WV-CU650 RS-485 System Controllers
- Up to 60 users
- Up to 16 recorders (WJ-HD716/WJ-HD616, WJ-HD300A Series, WJ-RT416 Series)
|
|
|
Camera
- Supports up to 256 cameras (using 8 Video Input Boards).
- All 256 channels are coaxial, multiplex cables, reducing the number of cables required and simplifying installation.
- Supports up to 256 RS-485, remote-controlled cameras.
- Pan, tilt and other lens motions can be controlled either by multiplex data over coaxial cable or RS-485 remote-control signals.
- Cables can be up to 1,200 m long (5C-2V coaxial cable).
System
- The maximum size (256 camera x 32 monitor) system requires four WJ-SX650/SX650U units.
- Set up is simple with the Video Input and Video Output Boards, each composed of a front-access Main Board and rear-access Rear Boards.
- Front access for Main Board and Power Supply maintenance.
- Rich array of sequence, alarm, and scheduling features meets every surveillance need.
- Supports up to 1,024 alarm inputs (Terminal/Camera/Recorder/Serial/Video Loss) and up to 64 alarm outputs (and also 1,024 Serial Alarm Out).
- Storage for up to 10,000 alarms, with alarm histories downloadable to PC to facilitate management.
- The Set-up Menu and WJ-SX650 Series Administrator Console make set up easy.
- Fine tune management of up to 60 users* with individual level and priority settings.
Monitor
- Output support for up to 32 monitors (using 2 Video Output Boards).
- Character displays show date, time, camera number, camera title and event information.
- Set-up menus are available in seven languages: English, French, Spanish, German, Italian, Russian, and Japanese.
- Alarm history display shows up to most recent 1,000 alarms.
Recorders
- Supports connection of up to 16 WJ-HD300A Series recorders (using 2 Video Output Boards). (WJ-HD300A Series)
- Use of WJ-HD300A Series network features allows remote surveillance from a PC.
Controllers
- Supports simultaneous use of up to 16 WV-CU650 System Controllers + personal computer (PC).
- Supports use of PS•Data (With DATA1 port set to PS Data).
|
|
|
|
|
|
|
| Power Source |
220 V - 240 V, 50 Hz
|
| Power Consumption |
60 W
|
| Ambient Operating Temperature |
–10 °C to +50 °C
|
| Ambient Operating Humidity |
Less than 90 %
|
| Video Input Board |
x 1
|
| Video Output Board |
x 1
|
| Expansion Slot |
x 1
|
| Alarm Output (ALARM OUT 1, 2) |
|
| RS-485 (Camera) Port |
6-conductor modular jack x 4(2-wire or 4-wire communication, With termination switches (MODE 1 to 4))
|
| Functions |
Monitor control (Camera selection,tour sequence, group sequence,group preset, OSD display) ,Camera/Receiver control(Coaxial/RS-485 communication),Recorder control, Alarm control(Alarm event, Alarm ACK, Alarm reset,Alarm suspension, Alarm History Display),Timer event, Camera event
|
| Dimensions (W x H x D) |
420 mm x 265 mm x 372 mm(excluding rubber feet and projections)
|
| Weight |
19.0 kg
|
| Expansion Slot |
x 3
|
| RS-485 (Camera) Port |
6-conductor modular jack x 12(2-wire or 4-wire communication, Withtermination switches (MODE 1 to 4))
|
| Extension Port(EXTENSION 1 IN, OUT) |
6-conductor modular jack x 2 (With a termination switch (TERM: ON, OFF))
|
| Extension Port(EXTENSION IN 2, 3) |
37-pin D-sub connector x 2
|
| Extension Port(EXTENSION OUT 2, 3) |
37-pin D-sub connector x 2
|
| Dimensions (W x H x D) |
420 mm x 265 mm x 372 mm(excluding rubber feet and projections)
|
| Weight |
18.0 kg
|
| Camera Input(CAMERA IN 1 to 32) |
1 V [p-p] / 75 O (BNC x 32), composite video signal
0.5 V [p-p] / 75 O data signal and
2.5 V [p-p] / 75 O vertical timing pulse multiplexed
|
| Video Output(VIDEO OUT 1 to 4) |
1 V [p-p] / 75 O (25-pin D-sub connector x 4),active loop-thru output
|
| Alarm Input(ALARM IN) |
N.O. (Normally Open contact) or N.C. (Normally Close contact) selectable x 32 (37-pin D-sub connector)
|
| Dimensions (W x H x D) |
|
| Main Board |
346 mm x 42 mm x 225 mm
|
| IN X-2 Board |
355 mm x 21 mm x 115 mm
|
| IN X-1 Board |
355 mm x 38 mm x 115 mm
|
| Monitor Output(MONITOR OUT 1 to 16) |
1 V [p-p] / 75 O (BNC x 16)
|
| Data Port (DATA 1 to 4) |
|
| DATA 1 |
Terminal Mode (TMNL)/PS•Data (PS•DATA) selectable
|
| DATA 2 |
Terminal Mode (TMNL)
|
| DATA 3, 4 |
Terminal Mode (TMNL)/Digital Disk Recorder (HDR) selectable 6-conductor modular jack x 4 (With termination switches (MODE 1 to 4))
|
| Alarm Output (ALARM OUT 1, 2) |
|
| Alarm Output |
Open collector output x 32, Max. 24 V DC, 100 mA
|
| Alarm Recover Input |
Non-voltage make contact input x 16
|
| Time Adjust Input |
Non-voltage make contact input x 1
|
| Time Adjust Output |
Open collector output x 32, Max. 24 V DC, 100 mA
|
| Extension Port(EXTENSION 1 IN, OUT) |
6-conductor modular jack x 2 (With a termination switch (TERM: ON, OFF))
|
| VS Input |
1 V [p-p] / 75 O (VS IN)
|
| VS Output |
(VS OUT (THRU)): VS loop-thru output,(VS OUT): 1 V [p-p] / 75 O (VS)
|
| Serial Port |
9-pin D-sub connector x 2
|
| Dimensions (W x H x D) |
|
| Main Board |
346 mm x 42 mm x 225 mm
|
| OUT X-3 Board |
355 mm x 21 mm x 115 mm
|
| OUT X-2 Board |
355 mm x 21 mm x 115 mm
|
| OUT X-1 Board |
355 mm x 38 mm x 115 mm
|
|
|
|
|
|
|
|
|
|